Control panel and keypad set SECOLINK PAS808+KM20B
Specifikacijos
SKU
U-3816948
Prekės kodas
CASPAS808KM20B
Tiekėjo prekės aprašymas
- 8 wired zones on the board
- 3 PGM outputs
- 4 areas
- 5 users
- Up to 7 keyboards
- PSTN communicator
| Control panel | |
| On-board wired zones | 8 |
| 2-wire smoke detector input | - |
| On-board wireless zones | - |
| Maximum zones in system | 8 |
| On-board PGM | 3 |
| Maximum PGM in system | 8 |
| User + installer codes | 5+1 |
| Duress code | X1, X2, X3, X4 (when X4 = X4 + 1) |
| Defaulting user code | Yes |
| Key switch zone | - |
| Partitions | 4 |
| "Shared" partition (common area) | - |
| System timers | - |
| Maximum keypads/modules in system | 7 |
| Event log buffer | 512 |
| PSTN communicator | In-built |
| In-built interface for backup communicator | TTL Serial |
| Data bus protocol | KRBUS |
| Total phone numbers: CMS reporting + personal dialing | 4 |
| Maximum phone numbers for personal dialing | Up to 4 |
| Maximum phone numbers for CMS reporting | Up to 4 |
| Reporting protocol | Contact ID |
| Voice guide for system control over PSTN | - |
| Voice guide for system programming over PSTN | - |
| "Roller" detector type | - |
| "Vibration" detector type | Yes |
| "Vibration" zone speed (sensitivity) | 0.01 - 0.25 sec. |
| Normal zone speed (sensitivity) | 0.1 - 2.5 sec. |
| Zone loop (detector) type | NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration |
| Arming mode | Away, Max Away, Night, Stay. |
| Zone definition | Entry/exit, entry/exit forced, interior, interior night armed, follower, interior night follower, perimeter, instant, PGM control; 24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature |
| Zone attributes | Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm |
| PGM definition | Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, exit/arm status, full arm status, power supply, resettable power supply, fire power supply, timer, mono/bi switch |
| PGM attributes | Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, disarm notification, clear alarm notification |
| Rated voltage of power supply (AC) | ~20 V |
| Minimum AC voltage (note: ~16 V input voltage lets control panel to generate max 0.7 A output current) | ~16 V |
| Maximum AC voltage (Note: higher than ~22 V voltage can damage control panel) | ~22 V |
| Maximum long term output current of control panel (I+AUX + I+BELL + I+PGM + battery charge): | ≤1.2 A |
| Maximum current of slow blowing fuse used in primary AC | 250 mA |
| Maximum AC power consumption | 150 mA |
| Minimum voltage on +AUX, +BELL, +PGM outputs | 12 V |
| Maximum voltage on +AUX, +BELL, +PGM outputs | 13.9 V |
| Maximum current out of +AUX | +0.8 A |
| Maximum current out of +BELL | +0.8 A |
| Maximum current into -PGM | -0.05 A |
| Maximum current out of +PGM | +0.8 A |
| Short circuit, overload protection of +BELL, +PGM, +AUX | Electronic |
| Battery charge, +BELL, +AUX current measurement | - |
| Failed (waste) backup battery disconnection | - |
| Maximum battery charging current | +0.4 A |
| Maximum current of fast blowing fuse used in battery circuit | 3.15 A |
| Control panel disconnect battery when it’s voltage less than | 9.5 V |
| Recommended backup battery | 12 V, 7 Ah / 20 Hr |
| Operational compliance | +EN50131, Grade2 |
| Overall dimensions W x H in mm | 145 x 77 |
| Environmental compliance | ROHS |
| Operating temperature | -10oC up to +50oC |
| Production status | In production |
| Latest firmware version | v0.03 |
| In-field firmware upgrade (by USB) | - |
| Keypad | |
| On-Board zones | 2 |
| On-Board PGM | - |
| Ambient temperature measurement | - |
| LCD type | 2 rows 16 symbols each |
| Keys in keypad | 20 |
| Programmable fast keys (F-Keys) | 32 |
| Data bus protocol | KRBUS |
| Zone loop (detector) type | NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL |
| Maximum wiring distance to CP | 300 m |
| Power supply | 9 - 14 V |
| Voltage measurement on keypad | Yes |
| Current consumption | Backlight on 100 mA, Baclight off < 50 mA. |
| On-Board sounder | Buzzer |
| Backlight color | Display = blue, keypad = yellow |
| Character set | Latin, Russian, Greek, East European, West European, Azeri, Turkish, Scandinavian. |
| User interface type | Advanced, Simple, Baltic, Asian. |
| Overall dimensions W x H in mm | 115 x 95 |
| Environmental compliance | ROHS |
| Operating temperature | 0oC up to +50oC |
| Interface for keypad settings programming | USB |
| Interface for keypad firmware updating | USB |
Tiekėjo specifikacijos
Product code
CASPAS808KM20B
Category
Control Panels
Supplier's product code
CASPAS808KM20B
Product ID
U-3816948
Tiekėjo pateikiama informacija apie prekę gali skirtis nuo realaus produkto. Jei pastebėjote neatitikimų praneškite apie tai el. paštu [email protected].